1″ GURU PC®

451-000000-035

DOWNLOAD REQUEST QUOTE
Freezing conditions which put water tanks and piping at risk for freeze damage occur when the car heat is turned off for switching locomotives or even brief layovers. The 1” GURU PC® valve is installed within the potable water bearing system on a passenger car to continuously monitor ambient temperatures and automatically drain the system before freeze damage can occur. Since the valve is completely mechanical, no electrical or air connections are required; however, an electric heater assembly is available to quickly heat up the valve after a drain occurrence. System Design Note: Valves are typically installed inside equipment cabinets or between the inner and outer car body. If a valve is to be installed outside or underneath the car, provide proper protection (e.g. skid plate) to avoid damage from impacts of roadside debris. All car designs should be properly validated and tested.
Valves placed in equipment cabinets tend to be colder than the heated passenger areas and take longer to heat back up when the car heat is restored. This can significantly delay the ability to refill the water systems and get the car back into service after a valve activation. The heater assembly causes the valve to heat up and close quickly. This allows refilling of the water system and getting the passenger car back into service as quickly as possible.
  • 2 LED lights for easy visual status check of power and heater
  • Fully encapsulated PC board
  • Self limiting heater
  • No moving parts to wear
  • Minimal electrical noise
  • Easy installation/removal with one hand or gloves
  • Heaters available: 120VAC/74VDC & 230 VAC
  • Exclusive Thermoloid® thermal actuator
  • No power or air required when used without heater
  • Low lead brass/bronze
  • Dual port seals
  • In-line serviceable
  • Eliminates costly freeze damage in passenger cars
  • Self-operating valve, no power or signal required
  • High flow design for rapid draining
  • Easy installation
  • Minimal maintenance required
  • NSF 61/372 Certified
  • Shock & Vibration tested
Series 1" GURU PC®
Description 1" GURU® PC
Size 1" NPT
Height-in 1-7/8
Height-mm 4.8
Weight lb 4.1
Weight kg 1.9
Cv 6.3
Maximum Operating Pressure 120 PSIG (8.3 BAR)
Opening Temperature 35°F (1.7°C)
Closing Temperature 45°F (7°C)
Operating/Storage Temp Range -67°F - 160°F (-55°C - 71°C)
Body Material Bronze
Isometric View Download
Front View Download
Top View Download
Side View Download